Part Number Hot Search : 
BD890YS PRF957 24S15 55N03 BPC1002 61FC4 2SC5289 EM8D100L
Product Description
Full Text Search
 

To Download HAS50-T050MI Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 H HiTRON
CHASSIS-MOUNT UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR POWER SUPPLIES 50 WATTS DUAL & TRIPLE OUTPUT HAS50-D & HAS50-T SERIES
FEATURES:
CHASSIS-MOUNT AC/DC MODULAR POWER SUPPLIES UNIVERSAL AC INPUT RANGE MEET UNIVERSAL SAFETY STANDARDS EMI MEETS CISPR PUB.22/FCC CLASS B CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: 90-264Vac typical. Nominal: 115/230Vac. Input Frequency: 47-63 Hz. (Nominal 50/60Hz.). Input Current: 0.76A @115Vac./0.39A @230Vac typical. Inrush Current: 4.8A(rms) or 34A(peak)@230Vac typical. Input Fuse: Use internal fuse. Dielectric Withstand: Meet IEC60950. 3,000Vac-Output/Input. 1,500Vac-Input/GND. 500Vac-Output/GND. EMI: Meet CISPR PUB. 22/FCC Class B. Hold-up time: 18 mS @115Vac, 82mS @230Vac typical. Earth Leakage: Less than 0.46mA @230Vac. Remote ON/OFF: ON(Enable)=Open. OFF(Disable)=Short.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Wattage: 50 Watts typical. Line Regulation: Various with output voltage. 0.1-0.5% typical. Load Regulation: Various with output voltage. Main VO1 1-2% typical. Aux.VO2 3-5% typical. (stacked on) Aux.VO3 2-3% typical. (P.R.) Noise & ripple: 1.0% typical peak to peak. OVP: Built-in on main output VO1. Adjustability: Available at main output VO1. Overload Protection (OLP): Fully protected against output overload and short circuit. Typical 125-150% of rating output load. Con2sult the factory for special OLP setting. Operating Temperature: -10C to +75C range. -10C to +50C @ full load without derating. From+50C derating linearly to half load @+75C
(Refer to the Derating Chart).
GENERAL SPECIFICATION
Efficiency: 78-83% typical various with output voltage. Switching Frequency: 68K Hz. Circuit Topology: Fixed Frequency Flyback circuit. Transient Response: Peak deviation on 200-220mV, Recovery time <3mSec.@ 25%step load change. Case: Impact resistant thermo-plastic enclosure. Safety Standard: EN60950/ UL1950 Class I or Class II. Power Density: 3.6 Watts. / Cubic inch. MTBF: 110,000Hrs. Mil Std 217, 25C.
Storage Temperature: -20C to +85C. Temperature Coefficient: 0.03% /C. Cooling: Convection cooling for +50C @ full load. At least 100LFM moving air is recommended for full load >+50C in a confined area. Commercial Grade only.
NOTE: (1) All measurements are at nominal input, full load, and +25C unless otherwise specified. (2) Load Regulation measured from Full-Load (F-L) to Half-Load (H-L) at nominal input and others loaded at half load.
In application Due to requests in market and advances in technology, specifications subject to change without notice.
-15-
OUTPUT VOLTAGE/ CURRENT RATINGS CHART
DUAL OUTPUT
MODEL NO. HAS50-D050E HAS50-D050I HAS50-D120I HAS50-D150K HAS50-D033E VO1 @ TYP. VOLT. 3.0A +5V 3.5A +5V 2.0A +12V 1.7A +15V 3.5A +3.3V TYP 3.0A 2.0A 2.0A 1.7A 3.0A VO2 VOLT. -5V +12V -12V -15V -5V
TRIPLE OUTPUT
MODEL NO. HAS50-T033EE HAS50-T033II HAS50-T033KK HAS50-T050II HAS50-T050KK HAS50-T050IE HAS50-T050MI VO1 @ TYP. 4.0A 4.0A 4.0A 3.5A 3.5A 3.5A 3.5A VOLT. +3.3V +3.3V +3.3V +5.0V +5.0V +5.0V +5.0V TYP. 2.0A 1.0A 0.8A 1.0A 0.8A 1.0A 0.5A VO2 VOLT. +5V +12V +15V +12V +15V +12V +24V TYP. 0.5A 0.5A 0.5A 0.5A 0.5A 0.5A 0.5A VO3 VOLT. -5V -12V -15V -12V -15V -5V -12V
Symbols: "" OVP built-in. "@" Adjustable. "" Stacked on main O/P. "" Installed with Post Regulator (P.R.). Note: (1) Max. (maximum load) is the continuous operating load of each rail, but the max. load of each rail can not be drawn from all outputs at the same time. (2) Peak output, less than 60 Sec. with duty cycle <10%.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 378.0g (13.3 Oz.) PIN ASSIGNMENT
PIN NO. P1-L P1-N P1-G P2-1 P2-2 P2-3 P2-4 P2-5 P2-6 DUAL O/P(+VO2) L N G REMOTE ON/OFF NC +VO2 VO1 DC COM DC COM DUAL O/P(-VO2) L N G REMOTE ON/OFF -VO2 NC VO1 DC COM DC COM TRIPLE O/P L N G REMOTE ON/OFF -VO3 +VO2 +VO1 DC COM DC COM
DERATING CHART
-16-


▲Up To Search▲   

 
Price & Availability of HAS50-T050MI

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X